A customer called the EMPF Helpline and asked for assistance in evaluating their rework process for a new Class 1 assembly process which failed In this case, visual inspection revealed the issue to be excessive fluxresidue remaining around the reworked solder joints, most likely due to improper cleaning after rework. Properly cleaning an assembly after rework is extremely important in maintaining board reliability. Ionic contamination left by flux residues can lead to corrosion and dendrite growth, two common causes of electronic shorts and opens. Identifying and implementing a cleaning solution for this assembly was necessary to greatly improve the reliability of the assembly. The EMPF offers various analytical techniques (ROSE, IC, FT-IR, SIR) to determine the root cause of contaminant problems, and to evaluate the effects of process or materials changes on cleanliness.
The recommended RMA flux removal method requires a saponifier heated from 100 to 150ºF to properly remove any residues. Deionized water is recommended for the final rinse. Reagent grade isopropyl alcohol (IPA) can also be used for manual cleaning by agitating with an acid brush. The affected board was cleaned using these methods and retested to verify Class 1 compliance. The more extensive cleaning process was proposed for implementation at the customer site in order to improve future reliability testing results.
|
|